Abstract

A detecting tube for nitrite and nitrate monitoring was developed as a spot test. The detecting tube was prepared by packing of poly(vinyl chloride) (PVC) particles coated with a quaternary ammonium salt into a mini-column. A nitrite solution was treated with sulfanilic acid and 1-naphthol; the resultant colored solution was drawn into the detecting tube by suction with a syringe, and a color band was formed in the tube. The color band length (CBL) corresponded to the nitrite concentration. Nitrate was also detected; after reduction with zinc. The nitrite and nitrate content of domestic wastewater samples was successfully detected by this method over the range of 0.5–45.3 mg-N L−1 as nitrogen concentration. Another type of detecting tube was prepared by alternately packing adsorbent and uncoated PVC particles in a mini-column. Colored zebra-bands were formed in this column, and the nitrite concentration was detected by counting the number of colored zebra-bands. Nitrite and nitrate concentrations in actual wastewater samples were detected more easily by this method, although the accuracy was somewhat lower than that obtained with the CBL method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.