Abstract

A method was developed using solid-phase microextraction (SPME) and gas chromatography to monitor the peppermint flavor loss in a taste-masked tablet formulation. This was accomplished by headspace sampling of two major components of peppermint: menthone and menthol. It was found that the excipients from the tablet produced an important matrix effect and that standard addition analysis was necessary for improved accuracy of the determination. The method was shown to be specific and precise. Furthermore, the method produced acceptable results with adequate quantitation limits to determine peppermint flavors in taste-masked tablets. The optimized extraction procedure was successfully used to monitor the stability of peppermint flavor in an oral solid formulation. The accelerated stability studies of the tablet showed that the menthone and menthol was lost in an exponential manner and levels off after several days of heat exposure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.