Abstract

A current collector with a solid-state discharger for 268 input and the same number of outgoing RK-50-9 RF cables from a high-voltage capacitive storage to the load is described. The spark discharger is started using a special initiator. The discharger design has a number of elements that reduce the self-inductance of the spark gap to 50 nH and increases the reliability of its operation via partitioning of cables (switching is performed by forming plasma contacts simultaneously at six points). The delay time of the discharger response is ~5.5 μs with an operation-time instability of approximately 500 ns.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.