Abstract

We developed a mid infrared (MIR) solar telescope, centered at 10 µm. Various optical layouts were analyzed based on computer simulations and a RitcheyChretien 6-inches telescope was selected with a plate scale of 2.5′′/mm using a pyroelectric 4 × 16 pixels detector. The angular resolution is 36′′/pixel with a field of view of 9.6′×2.4′. Two germanium filters are used, one at the aperture of thetelescope and another near its focal plane. The detector was characterized with alaboratory black-body. The count values follow a linear relation with the blackbody temperature. The control systems for both the telescope and the detectorwere developed. Proper mechanical supports were designed for the filters, detectorand electronics. The system has been integrated and a user interface was developed. Preliminary observations have been made giving a signal-to-noise ratio of ≈ 1000.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.