Abstract

Assessing the rotational alignment of the humeral component during total elbow arthroplasty is dependent upon bony landmarks that can be absent or altered in cases of distal humerus fractures, revision arthroplasty, severe bone loss, or deformity. We hypothesize that the intermuscular septum can be used as a reliable soft-tissue landmark to set the rotation of the humeral component intra-operatively when previously described bony landmarks are not reliable or present. Forty-eight unpaired cadaveric human subjects (mean age and standard deviation 63 ± 12 years; 24 males, 24 females) underwent computed tomography (CT) scans. The geometric centers of the trochlea and capitellum were assessed, and the line through these two points was set as the flexion-extension axis (FEA) of the elbow. The intermuscular septum axis (IMSA) was drawn proximal to the olecranon fossa and at least 4 cm proximal to the most distal point of the articular surface, where the posterior humeral cortex was flat. The angles between the FEA and IMSA were calculated and compared using a two-tailed t-test. Regression analysis was used to assess the inter- and intra-observer reliability of the IMSA. The IMSA was externally rotated 10.3° ± 2.8 compared to the FEA (p < 0.001 and confidence interval (CI) of 2.8 with α set to 0.01). The inter- and intra-observer reliability of the IMSA was high, with an R-value of 0.91 and 0.97, respectively. The intermuscular septum can be used as a soft-tissue landmark to set humeral component rotation and is 10.3° externally rotated with respect to the FEA of the ulnohumeral joint.