Abstract

The monitoring of chimerism status in a hematopoietic stem cell transplantation patient is a crucial process and is performed periodically in a short time interval. A short tandem repeat marker is widely used for chimerism analysis due to its high discrimination power. However, the sensitivity of this approach was limited to 5% of a minor contributor and the interpretation is usually interrupted with PCR stochastic phenomena. Here, we developed an SNP panel for chimerism analysis using TaqMan technology. A set of SNPs was selected from Thai ancestry informative markers and open-access databases with proper criteria. We examined the 30 recipient-donor pairs that underwent HSCT and showed that the panel can provide an informative marker from 90% of all pairs. An early detection of artificial chimerism in post-HSCT samples was observed when compared with STR analysis. In addition, the detail of cases was discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.