Okadaic acid (OA) is one of the main virulence factors of diarrheal shellfish toxins (DSP), which can cause acute carcinogenic or teratogenic effects after ingestion of contaminated shellfish. Therefore, high-sensitivity and fast detection of OA is a key to preventing the occurrence of safety accidents. In this paper, we effectively established a smartphone-assisted microarray immunosensor combined with an indirect competitive ELISA (iELISA) for quantitative colorimetric detection of OA. To further improve the detection sensitivity and match the smartphone imaging, a novel graphene oxide (GO) composite probe was developed to realize the multi-stage signal amplification. The system exhibited a wide linear range for the detection of OA (0.02–33.6 ng ·mL−1) with low detection limit of 0.02 ng ·mL−1. The recovery of OA in spiked shellfish samples was in the range of 80%–103.5%, which indicates the good applicability of this biosensor. The whole detection system has advantages of simplicity, low cost, high sensitivity and portability, which is expected to be a powerful alternative tool for on-site detecting and early warning of the pollution of marine products.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.