A total of 509 consecutive Branemark TM implants (Nobelpharma AB, Gothenburg, Sweden) were inserted in 146 patients between December 1982 and May 1989, on which 217 fixed partial dentures were planned. The cumulative failure rates after abutment connection were 3.9% and 4.1% for the maxillae and mandible, respectively. The lack of continuous prosthesis stability was limited to 4.1% for the maxillae and 5.4% for the mandible. The average annual marginal bone loss was 0.77 mm (SD = 1.0) and 0.96 mm (SD = 0.9) for the maxillae and mandible, respectively, during the first year and averaged 0.1 mm for the following years. The mode of connection between teeth and implants or the use of porcelain instead of composite resin as occlusal material did not influence the marginal bone height around the implants. Technical complications were most often related to the materials used. The results of a medium-term follow-up encourage the use of the Branemark osseointegration system in the treatment of partial edentulism.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.