Abstract
Real-time and sensitive detection of pathogenic bacteria in food is in high demand to ensure food safety. In this study, a single-walled carbon nanotubes (SWCNTs)-based electrochemical impedance immunosensor for on-site detection of Listeria monocytogenes (L. monocytogenes) was developed. A gold-plated wire was functionalized using polyethylenimine (PEI), SWCNTs, streptavidin, biotinylated L. monocytogenes antibodies, and bovine serum albumin (BSA). A linear relationship (R2 =0.982) between the electron transfer resistance measurements and concentrations of L. monocytogenes within the range of 103 -108 CFU/ml was observed. In addition, the sensor demonstrated high selectivity towards the target in the presence of other bacterial cells such as Salmonella Typhimurium and Escherichia coli O157:H7. To facilitate the demand for on-site detection, the sensor was integrated into a smartphone-controlled biosensor platform, consisting of a compact potentiostat device and a smartphone. The signals from the proposed platform were compared with a conventional potentiostat using the immunosensor interacted with L. monocytogenes (103 -105 CFU/ml). The signals obtained with both instruments showed high consistency. Recovery percentages of lettuce homogenate spiked with 103 , 104 , and 105 CFU/ml of L. monocytogenes obtained with the portable platform were 90.21, 90.44, and 93.69, respectively. The presented on-site applicable SWCNT-based immunosensor platform was shown to have a high potential to be used in field settings for food and agricultural applications. PRACTICAL APPLICATION: The developed immunosensor was developed for on-site detection of L. monocytogenes. The limit of detection of the sensor was 103 CFU/ml with a detection time of 10min. In order to facilitate the requirements for effective on-site screening for food safety, the sensor was integrated into a smartphone-controlled platform, so that the bio-molecular interactions were converted into impedance signals and transmitted wirelessly to a smartphone by a hand-held EIS transducer.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.