A new single-stage, single-switch power factor correction converter with output electrical isolation is proposed in this paper. The topology of this converter is derived by combining a boost circuit and a forward circuit in one power stage. To improve the performance of the AC-DC converter (i.e., good power factor correction, low total harmonic distortion (THD) and low DC bus voltage), two bulk storage capacitors are adopted. Its excellent line regulation capability makes the converter suitable for universal input application. Due to its simplified power stage and control circuit, this converter presents a better efficiency, lower cost and higher reliability. Detailed steady state analysis and design procedure are presented. To verify the performance of the proposed converter, a design example along with P-simulation program with integrated circuit emphasis (PSPICE) simulation and experimental implementation are given. The measured power factor and efficiency are 99% and 87% at low line (i.e. 110 VAC) operation, and 95% and 81% at high line (i.e. 220 VAC) operation, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.