Abstract

A single-stage G-M type pulse tube cooler (PTC) was designed and tested to explore the lowest attainable refrigeration temperature and to further improve the cooling performance in the temperature range of 15–40 K. The magnetic material Er 3Ni was used as part of the regenerative material besides the phosphor-bronze and the lead so as to improve the efficiency of the regenerator. With an input power of 6 kW, a lowest no-load refrigeration temperature of 12.6 K was obtained, which is a new record for the single-stage PTC. The cooling capacity at 15–40 K was also significantly improved, which may extend the application of the single-stage PTC for the cooling of superconductors and cryopumps.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call