Abstract

We reviewed outcomes in all 36 consecutive children <5 kg supported with the Berlin Heart pulsatile ventricular assist device (VAD) at the University of Florida, comparing those with univentricular circulation (n = 23) to those with biventricular circulation (n = 13). The primary outcome was mortality. Kaplan-Meier methods and log-rank tests were used to assess group differences in long-term survival after VAD insertion. T-tests using estimated survival proportions and standard errors were used to compare groups at specific time points. Of all 82 patients ever supported with Berlin Heart at our institution, 49 (49/82 = 59.76%) weighed <10 kg and 36 (36/82 = 43.90%) weighed <5 kg. Of these 36 patients who weighed <5 kg, 26 (26/36 = 72.22%) were successfully bridged to transplantation. Of these 36 patients who weighed <5 kg, 13 (13/36 = 36.1%) had biventricular circulation and were supported with 12 biventricular assist devices (BiVADs) and 1 left ventricular assist device (LVAD) (Age [days]: median = 67, range = 17-212; Weight [kilograms]: median = 4.1, range = 3.1-4.9), while 23 (23/36 = 63.9%) had univentricular circulation and were supported with 23 single ventricle-ventricular assist devices (sVADs) (Age [days]: median = 25, range = 4-215; Weight [kilograms]: median = 3.4, range = 2.4-4.9). Of 13 biventricular patients who weighed <5 kg, 12 (12/23 = 92.3%) were successfully bridged to cardiac transplantation. Of 23 functionally univentricular patients who weighed <5 kg, 14 (14/23 = 60.87%) were successfully bridged to cardiac transplantation. For all 36 patients who weighed <5 kg: 1-year survival estimate after VAD insertion = 62.7% (95% confidence interval [CI] = 48.5%-81.2%) and 5-year survival estimate after VAD insertion = 58.5% (95% CI = 43.8%-78.3%). One-year survival after VAD insertion: 84.6% (95% CI = 67.1%-99.9%) in biventricular patients and 49.7% (95% CI = 32.3%-76.4%) in univentricular patients, P = 0.018. Three-year survival after VAD insertion: 84.6% (95% CI = 67.1%-99.9%) in biventricular patients and 41.4% (95% CI = 23.6%-72.5%) in univentricular patients, P = 0.005. Pulsatile VAD facilitates bridge to transplantation in neonates and infants weighing <5 kg; however, survival after VAD insertion in these small patients is less in those with univentricular circulation in comparison to those with biventricular circulation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.