Abstract

ABSTRACTThis paper proposes a single clock charge pump with high-voltage conversion ratio for low-voltage applications. To increase the clock voltage level, a voltage doubler circuit has been used in the charge pump circuit. In each stage of this voltage doubler circuit, two out of phase clock signals are produced, meanwhile there is a charge transfer switch in every single stage that it's input is dynamically controlled by an inverter that turns the switch on and off completely. The four-stage charge pump is simulated by using Hspice software under 0.18 µm process with 1.8 V supply voltage and clock voltage. The output voltage and the conversion ratio of the charge pump are 14.71 V and 74.3%, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.