Abstract

Introduction The meniscus plays a vital role in maintaining knee stability. It acts as a shock absorber and knee filler. The incidence of meniscal tears is estimated to be 60 per 100,000 people. Due to lack of awareness among patients, only 10% of the meniscus tears were treated through partial or total meniscectomy. Recently, the concept of meniscus preservation surgery has emerged to preserve early degeneration of the knee joint. In the current retrospective study, safety and functional outcomes of arthroscopic meniscal repair surgery using SurestitchAll inside implants (Sironix Arthroscopy Solutions, Healthium Medtech Limited, Bengalaru, India) were assessed. Methods Fifty-two patients who underwent arthroscopic meniscal repair surgery between January 2019 to July 2022 at Epic Hospital in Gujarat, India, were enrolled in the study. Retrospective data including demographics, injury details, surgery details, and post-surgery complications were collected from the medical records of the patients. Then, the patients were followed up telephonically to document safety and functional outcomes using patient-reported instruments such as International Knee Documentation Committee (IKDC) score, Single Assessment Numeric Evaluation (SANE) score, Tegner activity level, and Lysholm knee score. Results The recruited patients had the mean age, height, and weight of 37.56 ± 12.52 years, 167.61 ± 7.28 cm, and 75.87 ± 10.7 kgs, respectively. Seventy-one percent of patients were male and 29% were female. Majority of the patients had the routine of doing mild exercise. During pre-surgery representations, medial meniscal tear was observed in majority of patients. The mean length of the tear was 1.32 ± 0.84 cm. In addition, patients were also diagnosed with anterior cruciate ligament (ACL), posterior cruciate ligament (PCL), medial collateral ligament (MCL) tears, and osteochondral defects. Surgeries for meniscal repair were performed using Surestitch All inside implant. In patient-reported outcomes, the mean IKDC, SANE, and Lysholm scores were 81.72 ± 14.23, 94.02 ± 13.79, and 93.32 ± 14.63, respectively. When the mean Tegner scores of pre-injury and post-surgery periods were compared, this resulted in no significant difference (p>0.05) in the activity levels of the patients. Conclusion Based on our findings, arthroscopic meniscal repair with Surestitch All inside meniscal repair implant provides satisfactory and favorable functional outcomes with no remarkable adverse events.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call