Abstract
To determine the visual and refractive outcomes of 210-degree arc length intrastromal corneal ring segment (ICRS) implantation in eyes with pellucid marginal corneal degeneration (PMCD). Retrospective, consecutive case series. Sixteen consecutive eyes of 10 patients who underwent a single 210-degree ICRS implantation by femtosecond laser for the management of PMCD and completed at least 1 year follow-up were included. A complete ophthalmic examination was performed preoperatively and postoperatively, including uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest spherical and cylindrical refractions, spherical equivalent, and keratometric readings. The mean follow-up period was 30.7 months (range 12 to 36 months). No intraoperative complication was observed. White deposits around the segments were noted in 2 of 16 eyes (12.5%) at the first postoperative year. The mean UCVA showed significant improvement, from 1.69 +/- 1.02 logarithm of the minimal angle of resolution (logMAR) preoperatively to 0.64 +/- 0.43 logMAR at the 36th month (n = 11, P < .001). The mean preoperative BSCVA was 0.88 +/- 0.68 logMAR; after 36 months, this improved to 0.35 +/- 0.34 (P < .001). At the 36th month, UCVA was improved in all eyes (n = 11, range: gain of 1 to 6 lines), whereas BSCVA was improved in 9 eyes (81.8%, range: gain of 2 to 7 lines) and remained unchanged in 2 eyes (18.1%); UCVA was 20/40 or better in 3 eyes (27%) and BSCVA was 20/40 or better in 8 eyes (72.7%). There was a significant reduction in the spherical equivalent refractive error, from -4.40 +/- 1.85 diopters (D) preoperatively to -1.86 +/- 0.60 D (P < .001), and the mean maximum keratometric power decreased from 49.70 +/- 4.32 D to 46.08 +/- 2.84 D (P < .001) after 36 months. The mean cylindrical refraction decreased from -4.39 +/- 1.86 D preoperatively to -2.38 +/- 1.35 D at 36 months (P < .001). A single 210-degree arc length ICRS implantation using a femtosecond laser for patients with PMCD provides good visual and refractive outcomes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.