Abstract

Recently the strip wound toroidal cores have increasingly been used in switching mode and uninterruptible power supplies for a wide range of industrial applications. Therefore, the prediction of iron loss increase in such magnetic cores energised by non-sinusoidal voltage excitation is important step in the design of electromagnetic devices. In this investigation, a loss increase was estimated by determination of unknown constants in a previously developed loss separation model using genetic algorithms. Also the skin effect of flux density was taken into account for estimation of power loss under pulse width modulated voltage sources. The results obtained are in good agreement with the measured results in wound toroids at various flux densities.