Abstract
A simplified degradation model for the continuous γ-irradiation of MEK in aerated aqueous solutions has been constructed using previously reported experimental studies and detailed kinetic model studies (Driver, P.A., Glowa, G.A., Wren, J.C., Radiat. Phys. Chem. 57(1), 37; Glowa, G.A., Driver, P.A., Wren, J.C., Radiat. Phys. Chem. 58(1), in press). The simplified model, consisting of only seven reactions and four equilibria, reproduces the experimental data and the full model results of the behaviour of MEK and the intermediate decay products and pH during the radiolysis reasonably well. The simplified model also reproduces the full model results on the dose profiles of water radiolysis products such as H , e − eq, OH, O − 2 and H 2O 2 very well. In this paper, the simplified model is described and the results are compared with the experimental data and simulation results from the full model.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.