Abstract
In this paper, we have developed a calculation method for estimating heat fluxes from ceiling radiant panels, using pipe density on panels and the temperature difference between the room air and the supply water. We then measured heat fluxes from panels in an environmental test room. After comparing the values estimated by our calculation method to the experiment's data, the calculated values closely match the values obtained from experiments, which means that this calculation method is practical in estimating the radiant panel performance in the design phase.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.