Abstract

Cold-formed thin-walled steel sections are usually used as the load-bearing elements of wall panels in building construction. Such panels consist of channel steel sections with gypsum plasterboard layers attached to the flanges on the outside and interior insulation. This paper proposes a simple method to calculate temperature distributions in the steel section when the panel is exposed to fire from one side. This method calculates the average temperatures in the flanges of the steel section and assumes that the temperature in the web is linear. The proposed method is based on simple heat balance analysis for a few nodes representing the key components of the panel. The thermal resistance of these nodes is obtained from the weighted average of thermal resistances in an effective width of the panel within which heat transfer in the panel width direction is assumed to occur. The effective width of the panel for calculating the weighted average of thermal resistances can be taken as the steel section flange width plus 15% of the difference between 300mm and the flange width of the steel section. Validity of the proposed method has been checked by comparison of the temperature results between the proposed 1-D modelling and 2-D ABAQUS Finite Element modelling for an extensive set of parametric and sensitivity studies covering different steel section dimensions (width, depth, thickness and lips), different spacing between steel section, number of gypsum layers (1 or 2) and different interior insulation properties. Further assessment of accuracy of the proposed temperature calculation method has been provided by comparing compressive resistance of the steel studs between using temperature profiles produced by 2-D ABAQUS Finite Element simulation and by using the proposed simplified method. Although the simplified method still requires a numerical procedure, it is extremely easy to implement to give designers of this structural system a much more efficient tool than using Finite Element simulations to calculate its fire resistance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.