Abstract

Extraction of a well-fixed ceramic liner during revision total hip arthroplasty can be technically challenging, particularly when acetabular fixation screws prevent en bloc removal of the shell and insert without causing collateral damage to the adjacent pelvic bone. It is also important to remove the ceramic liner intact, as ceramic debris left in the joint may cause third body wear with premature articular wear of the revised implants. We describe a novel technique to extract an incarcerated ceramic liner when previously described strategies prove ineffective. Knowledge of this technique will help surgeons avoid unnecessary damage to the acetabular bone and optimize prospects for stable implantation of revision components.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.