Abstract

A simple NFC (near field communication) RF performance measurement method based on ISO/IEC 14443 standard was presented in this article. The measurement procedure of three test items, namely off-keying duration time evaluation, H-field strength measurement and NFC system RF performance evaluation were illustrated. The cross spiral-loop antenna structure is presented to be a reading (and Tag) antenna, which will increase the antenna impedance and quality factor (Q). By using the real-time spectrum analyzer and oscilloscope, the evaluating equation will be derived which consists all conversion and correction factors. Experimental results are shown to verify the validity of theoretical work.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.