We demonstrate that by using a syringe needle, plastic tubing, two glass capillaries and epoxy glue a microfluidic device can be fabricated straightforwardly that allows for the production of double emulsions, or in other words the generation of droplets-in-droplets. The device in essence is a serial combination of droplet generation by co-flow and a T-junction. To reduce potential issues with channel wetting, we established that an “obstructed” T-junction outperformed a conventional T-junction. We illustrate the versatility of our device through production of a range of polymer microcapsules, including ones that contain a waterborne dispersion of colour changing pigment, and microcapsules with compartmentalized ferrofluidic segments, that is capsules that contain more than one droplet of ferrofluid.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.