Abstract

In respiratory gated radiotherapy,low latency between target motion into and out of the gating window and actual beam-on and beam-off is crucial for the treatment accuracy. However, there is presently a lack of guidelines and accurate methods for gating latency measurements. To develop a simple and reliable method for gating latency measurements that work across different radiotherapy platforms. Gating latencies were measured at a Varian ProBeam (protons, RPM gating system) and TrueBeam (photons, TrueBeam gating system) accelerator. A motion-stage performed 1cm vertical sinusoidal motion of a marker block that was optically tracked by the gating system. An amplitude gating window was set to cover the posterior half of the motion (0-0.5cm). Gated beams were delivered to a 5mm cubic scintillating ZnSe:O crystal that emitted visible light when irradiated, thereby directly showing when the beam was on. During gated beam delivery, a video camera acquired images at 120Hz of the moving marker block and light-emitting crystal. After treatment, the block position and crystal light intensity were determined in all video frames. Two methods were used to determine the gate-on (τon ) and gate-off (τoff ) latencies. By method 1, the video was synchronized with gating log files by temporal alignment of the same block motion recorded in both the video and the log files. τon was defined as the time from the block entered the gating window (from gating log files) to the actual beam-on as detected by the crystal light. Similarly, τoff was the time from the block exited the gating window to beam-off. By method 2, τon and τoff were found from the videos alone using motion of different sine periods (1-10s). In each video, a sinusoidal fit of the block motion provided the times Tmin of the lowest block position. The mid-time, Tmid-light , of each beam-on period was determined as the time halfway between crystal light signal start and end. It can be shown that the directly measurable quantity Tmid-light - Tmin =(τoff +τon )/2, which provided the sum (τoff +τon ) of the two latencies. It can also be shown that the beam-on (i.e., crystal light) duration ΔTlight increases linearly with the sine period and depends on τoff - τon : ΔTlight =constant•period+(τoff - τon ). Hence, a linear fit of ΔTlight as a function of the period provided the difference of the two latencies. From the sum (τoff +τon ) and difference (τoff - τon ), the individual latencies were determined. Method 1 resulted in mean (±SD) latencies of τon =255±33ms, τoff =82±15ms for the ProBeam and τon =84±13ms, τoff =44±11ms for the TrueBeam. Method 2 resulted in latencies of τon =255±23ms, τoff =95±23ms for the ProBeam and τon =83±8ms, τoff =46±8ms for the TrueBeam. Hence, the mean latencies determined by the two methods agreed within 13ms for the ProBeam and within 2ms for the TrueBeam. A novel, simple and low-cost method for gating latency measurements that work across different radiotherapy platforms was demonstrated. Only the TrueBeam fully fulfilled the AAPM TG-142 recommendation of maximum 100ms latencies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.