Abstract

Discomfort glare rating (DGR) and Unified glare rating (UGR) are main models currently used as discomfort glare evaluation systems, both of which are calculated employing four factors including the luminaire size, the luminaire position relative to the observer, background luminance, and the luminaires number and location. This study aims at proposing a simple solution for reducing DGR and thereby increasing visual comfort perception (VCP) in an interior lighting system. The proposed solution is based solely on variations of luminaire surface area without change in other factors, e.g. candlepower and number and location of luminaires in the lighting system. To this end, firstly, the equations related to DGR were modified for a desired luminaire, and, secondly, by solving the modified equations, the new luminaire surface area was obtained, which caused DGR decrease and VCP improvement. Finally, by some modifications in the location of selected luminaires having main role on DGR, the VCP rose considerably.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.