Abstract

A qualitative method to verify the presence of parametric oscillations at ${f_{0}}/{2}$ in power amplifiers (PAs) is presented and validated. It relies on the simultaneous application of fundamental and subharmonic tones to trigger possible parametric oscillations and can be implemented in any commercial harmonic balance solver without requiring any external software that may be expensive or however not available to the designer. Wide applicability is guaranteed by the fact that this method does not require access to any internal node of the circuit. In fact, the amplifier is handled as a black-box where only the input and output ports are accessible. The stability check is first demonstrated on a simplified case study and then validated on a real K-band integrated PA, where it correctly reproduces with simulations the parametric oscillations observed by measurements. On the redesigned amplifier, the proposed test predicted the absence of oscillations, which has been confirmed by the experimental characterization.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.