Abstract

This paper presents a simple method to determine double-cage rotor equivalent circuit parameters of induction motors (IMs). A new formula to calculate the double-cage rotor equivalent circuit parameters is proposed. The formula is sufficiently simple to be calculated by a calculator but can determine the parameters of outer- and inner-cage conductors. The proposed method takes the magnetic saturation effect of a closed-slot rotor into account and applies to not only double-cage but also single-cage IMs. All equivalent circuit parameters can be determined using only classical no-load and locked-rotor tests. Thus, the proposed method is suitable to be used as a standardized testing method for IMs. The validity of the proposed method is demonstrated by experimental results on four 5.5 kW-200 V-4 P-22 A-50 Hz IMs: double- and single-cage IMs with semi-closed- and closed-slot rotors.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.