Abstract

SummaryWe have put forward a method to be used in the field of nuclear medicine, for calculating internally absorbed doses in patients. The simplicity and flexibility of this method allow one to make a rapid estimation of risk both to the individual and to the population. In order to calculate the absorbed doses we based our procedure on the concept of the mean absorbed fraction, taking into account anatomical and functional variability which is highly important in the calculation of internal doses in children. With this aim in mind we prepared tables which take into consideration anatomical differences and which permit the calculation of the mean absorbed doses in the whole body, in the organs accumulating radioactivity, in the gonads and in the marrow; all this for those radionuclides most widely used in nuclear medicine. By comparing our results with dose obtained from the use of M.I.R.D.'s method it can be seen that when the errors inherent in these types of calculation are taken into account, the results of both methods are in close agreement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.