Abstract

A simple isocratic reversed-phase high performance liquid chromatographic (RP-HPLC) method was developed for determination of oseltamivir active pharmaceutical ingredient (API) in bulk drug and pharmaceuticals. The separation was achieved on a Purospher STAR® RP – 18e column with a mobile phase consisting of methanol- 0.02 mol l-1 phosphate buffer, pH 5, 50:50 (v/v). Chromatographic results demonstrated the specificity of the method for determination of oseltamivir in presence of degradation products generated in studies of forced decomposition. The limit of detection (LOD) and limit of quantification (LOQ) for oseltamivir phosphate were 0,0162 μg ml-1 and 0,0491 μg ml-1, respectively. The advantages of this method include simple sample treatment and short elution time (less than 6 min). Furthermore, using methanol instead of acetonitrile in a mobile phase composition considerably reduces the laboratory expenses, still retaining adequate sensitivity for routine analysis as well as for evaluation of potentially counterfeit Tamiflu® products.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call