Abstract
Obtaining excellent exposure of the papillary muscles is challenging in minimally invasive mitral valve repair. We have developed a simple and effective technique using a sterile paper ruler. The ruler is cut to the proper length (8 to 12 cm) depending on the valve size, then rolled and sutured. The rolled ruler, 7 to 11 cm in circumference, is placed inside the mitral leaflets. This technique provides excellent exposure of the papillary muscles without damaging the leaflets and prevents chordal injury during artificial chordal implantation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.