Abstract

A simple, direct radioimmunoassay for cortisol in human serum and plasma is described. An antiserum, raised in sheep to a cortisol-3-(O-carboxymethyl)oxime/bovine serum albumin conjugate, is coupled to microcellulose. No extraction is required because plasma samples and standards are incubated with the antiserum and an 125I radioligand in a low-pH buffer, which denatures cortisol-binding globulins. The assay satisfies accepted validation criteria. In addition, results from the radioimmunoassay compare well with those obtained by a gas chromatographic-mass spectrometric technique (r = 0.968; FRIA = 0.97 FGCMS + 2.0 nmol/L). The latter procedure features the very high intrinsic specificity obtained by selected ion monitoring at high mass-spectrometric resolution (M/deltaM = 8500) with a Varian MAT-731 instrument. The simplicity of the radioimmunoassay procedure, with use of reagents prepared "in house," makes this a very practical and economical assay for use in the medium or large endocrine laboratory.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.