A new, simple and rapid gas chromatographic method was developed for the determination of N-methylpyrrolidine (NMP) in cefepime and its preparation. NMP was extracted with chloroform from cefepime and its preparation. An HP-1 column was maintained at 100 °C. Both the injector and the FI detector were set 250 °C. Pyridine was used as an internal standard. The detector response was linear up to 135 ng. The detection limit was 0.3 ng. The recoveries were 100.2–103.0% at three concentration levels. No interference from organic solvents presented in the synthesis was observed. The proposed method has a potential for application in quality control for cefepime and its preparation.