Abstract

A simple and safe technique for performing an endoscopic third ventriculocisternostomy is described using a small-diameter semirigid neuroendoscope in conjunction with a perforated ventricular catheter to bluntly fenestrate the floor of the third ventricle. All previous descriptions involve the initial use of an introducer sheath that in our experience lends to loss of cerebrospinal fluid, consequently distorting the anatomic landmarks of the third ventricle as well as compromising the crucial concave shape of its floor. Our technique limits the loss of cerebrospinal fluid volume, therefore, reducing the chance of basilar artery complex perforation as a consequence of distortion of third ventricular landmarks and loss of third ventricular floor concavity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.