Abstract

AbstractSubsurface exploration relies on drilling. Normally drilling requires a drilling fluid that will infiltrate into the drill core. Drilling fluid contains non‐indigenous materials and microbes from the surface, so its presence renders a sample unsuitable for microbiological and many other analyses. Because infiltration cannot be avoided, it is of paramount importance to assess the degree of contamination to identify uncontaminated samples for geomicrobiological investigations. To do this, usually a tracer is mixed into the drilling fluid. In past drilling operations a variety of tracers have been used, each has specific strengths and weaknesses. For microspheres the main problem was the high price, which limited their use to spot checks or drilling operations that require only small amounts of drilling fluid. Here, we present a modified microsphere tracer approach that uses an aqueous fluorescent pigment dispersion with a similar concentration of fluorescent particles as previously used microsphere tracers. However, it costs four orders of magnitude less, allowing for a more liberal use even in large operations. Its applicability for deep drilling campaigns was successfully tested during two drilling campaigns of the International Continental Drilling Program (ICDP) at Lake Towuti, Sulawesi, Indonesia, and Lake Chalco, Mexico. Quantification of the tracer requires only a fluorescence microscope or a flow cytometer. The latter allowing for high‐resolution data to be obtained directly on‐site within minutes and with minimal effort, decreasing sample processing times substantially relative to traditional tracer methods. This approach offers an inexpensive, rapid, but powerful alternative technique for contamination assessment during drilling campaigns.

Highlights

  • Tests confirmed the applicability of our new tracer method for large drilling campaigns with volumes of drilling fluid in the order of tens to hundreds of thousands of liters

  • The sensitivity of the new method is similar to the established microsphere tracer approach but it offers two major improvements

  • This opens the possibility to select samples of highest quality with respect to contamination and to decide whether changes in drilling techniques are required to optimize core quality

Read more

Summary

Introduction

We present a modified microsphere tracer approach that uses an aqueous fluorescent pigment dispersion with a similar concentration of fluorescent particles as previously used microsphere tracers It costs four orders of magnitude less, allowing for a more liberal use even in large operations. Quantification of the tracer requires only a fluorescence microscope or a flow cytometer The latter allowing for high-resolution data to be obtained directly on-site within minutes and with minimal effort, decreasing sample processing times substantially relative to traditional tracer methods. This approach offers an inexpensive, rapid, but powerful alternative technique for contamination assessment during drilling campaign

Methods
Conclusion
Full Text