Abstract

Rectifier reverse-recovery problems cause a significant efficiency reduction as well as severe electromagnetic interference (EMI) in continuous-current-mode (CCM) boost converters. To alleviate these problems, this paper presents a simple and effective solution that involves shifting the original rectifier current to a new branch, which consists of a rectifier and a coupled winding of the boost inductor. When the active switch turns on, the current through the original boost rectifier is zero and the current decrease rate di/dt in the new branch is controlled by the leakage inductor. Based on the operation analysis, design issues to guarantee complete current shift are also addressed. Applying the proposed concept to a 500 W CCM DC/DC boost converter and a 500 W CCM power factor correction (PFC) boost converter with universal-line input generates a 2% efficiency improvement. The same concept can be easily extended to other basic DC/DC and CCM PFC converters.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.