Abstract

The accurate measurement of efficiency in wide band-gap semiconductor based converters, wherein efficiencies over 98% are achievable, is a challenge. In this work, a simple, open-loop, experimental dc-ac-dc back-to-back power conversion methodology is presented for the measurement of the combined losses of the power converter and passive filter. Additionally, only the power loss needs to be supplied by the source, although each converter sees active loading. The open-loop control mechanism for real and reactive power (power factor) control is explained, and also accuracy comparison with typical input and output power measurement method is provided. The simulation results of the proposed method are presented with experimental validation using a 1200 V SiC MOSFET based 4.6 kW — single phase (equivalent to 13.8 kW–3 phase) back-to-back conversion system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.