Abstract
This paper describes a thermal transpiration-driven multistage Knudsen pump for vacuum pumping applications. This type of pump relies upon the motion of gas molecules from the cold end to the hot end of a channel in which the flow is restricted to the free molecular or transitional regimes. To achieve a high compression ratio, 48 stages are cascaded in series in a single chip. A five-mask, single silicon wafer process is used for monolithic integration of the designed Knudsen pump. The pump has several monolithically integrated Pirani gauges to experimentally measure the vacuum pumping characteristics of the pump. It has a footprint of 10.35 × 11.45 mm2. For an input power of 1350 mW, the fabricated pump self-evacuates the encapsulated cavities from 760 to ≈50 Torr, resulting in a compression ratio of 15. It also pumps down from 250 to ≈5 Torr, resulting in a compression ratio of 50. Each integrated Pirani gauge requires ≈3.9 mW of power consumption, and its response is sufficiently sensitive in the operating pressure range of 760–1 Torr.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.