Abstract

A surge in a centrifugal compressor can cause critical damage to the compressor, resulting in large repair costs, so one of the most important considerations in the design of compressor systems is to prevent a surge. However, conventional methods to size recycle valves in anti-surge systems are limited in that the valve characteristics and time delay cannot be quantitatively considered. This paper suggested a short-cut graphical method to easily size the recycle valves in an anti-surge system by considering the valve characteristics, including the dead time, actuation time, and opening types. Dynamic simulations were carried out to verify the resulting size of the valves, and the results of the simulation showed that a surge could be avoided effectively and economically.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.