Abstract

This paper proposes a sensorless pulse-width modulation (PWM) pulse skipping method for detecting discontinuous or continuous conduction mode in multi-mode synchronous converters. The gate signal of the synchronous rectifier switch is skipped periodically and the output voltage is observed to determine the conduction mode.. The proposed method can determine the optimal conduction mode, which results in improved efficiency over a wide load range. This method is particularly well suited for digital controller implementation and requires only an output voltage sensor. A synchronous buck converter with 20 V/5 A output is built and tested to verify the proposed algorithm's performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.