Abstract

AbstractThe electrooxidation of epinephrine (EPI) and piroxicam (PRX) has been investigated by application of nickel hydroxide nanoparticles/multiwalled carbon nanotubes composite electrode (MWCNTs‐NHNPs/GCE) using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry (CA) methods. The modified electrode showed suitable electrochemical responses for EPI and PRX determination. Under the optimum conditions the electrode provides a linear response versus EPI and PRX concentrations in the range of 1–220 µM and 0.7–75 µM, respectively using the DPV method. Linear responses versus EPI and PRX concentrations in the range of 1–1000 µM and 1–800 µM, respectively, were obtained using the CA method. The modified electrode was used for determination of EPI and PRX in human urine with satisfactory results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.