Abstract

A novel CL method for the determination of tannic acid (TA) was established based on TA inhibition of the chemiluminescence (CL) emission of the luminol-hydrogen peroxide CL system catalysed by tetrasulphonated manganese phthalocyanine (MnTSPc) under alkaline conditions. The peak height is proportional to the natural logarithm of concentration of TA in the range 1.0 x 10(-7)-3.0 x 10(-10) mol/L with a detection limit of 5.6 x 10(-11) mol/L and the relative standard deviation was 2.5% for the determination of 1.0 x 10(-8) mol/L TA (n = 11). The proposed method has been successfully applied to the determination of TA in Chinese gall and industrial wastewater.