Abstract

For point-of-care testing of the illegal fortification of repaglinide (Rep) in natural dietary supplements, a competitive chemiluminescent immunoassay (CLIA) was established, using a horseradish peroxidase (HRP)-luminol-H2O2 system for signal amplification. Polyclonal antibodies for Rep were produced via immunization technique. Following optimization of the enzyme reaction time and concentrations of antibody and coating antigen, the method showed a limit of quantification (LOQ) of 1.0ng/mL in PBS and limit of detection (LOD) of 8.3ng/mL in serum and 6.0ng/mL in blank tablets. When applied in natural dietary supplements, the method provided results consistent with those from HPLC, suggesting that the proposed method could be used for rapid screening of Rep in natural dietary supplements and detecting Rep in serum after administration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.