Abstract

In this work, pyrrole-histidine has been designed, synthesized and, used as a novel functional monomer to fabricate a molecularly imprinted electrochemical sensor for the selective and sensitive detection of teriflunomide (TER). The molecularly imprinted thin film of electrochemical sensor was constructed by directly electropolymerization of co-polymer of pyrrole-histidine (PyHis) with pyrrole in the presence of a template, TER, on a glassy carbon electrode (GCE). After electropolymerization, the structure and morphology of the fabricated MIP sensor were characterized by Fourier-transform infrared spectroscopy (FT-IR) and scanning electron microscopy (SEM) and its electrochemical parameters such as cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS). The poly (pyrrole-co-pyrrole-histidine) [Poly (Py-co-PyHis)]@MIP/GCE sensor have a linear TER concentration in the of 0.1–1.0 pM with a low detection limit of 11.38 fM. The present strategy for electrochemical sensor have been also showed excellent recovery in synthetic serum samples and tablet dosage form with the recoveries 97.56% and 100.35%, respectively. The developed [Poly (Py-co-PyHis)]@MIP/GCE sensor exhibited an excellent electrochemical response for TER due to the synergistic effect of conducting polymer and molecularly imprinting techniques.