Abstract

This paper proposes a semi-supervised autoencoder with an auxiliary task (SAAT) to extract a health feature space for power transformer fault diagnosis using dissolved gas analysis (DGA). The health feature space generated by a semi-supervised autoencoder (SSAE) not only identifies normal and thermal/electrical fault types, but also presents the underlying characteristics of DGA. In the proposed approach, by adding an auxiliary task that detects normal and fault states in the loss function of SSAE, the health feature space additionally enables visualization of health degradation properties. The overall procedure of the new approach includes three key steps: 1) preprocessing DGA data, 2) extracting two health features via SAAT, and 3) visualizing the two health features in two-dimensional space. In this paper, we test the proposed approach using massive unlabeled/labeled Korea Electric Power Corporation (KEPCO) databases and IEC TC 10 databases. To demonstrate the effectiveness of the proposed approach, four comparative studies are conducted with these datasets; the studies examined: 1) the effectiveness of an auxiliary detection task, 2) the effectiveness of the visualization method, 3) conventional fault diagnosis methods, and 4) the state-of-the-art, semi-supervised deep learning algorithms. By examining several evaluation metrics, these comparative studies confirm that the proposed approach outperforms SSAE without the auxiliary task, existing methods, and state-of-the-art deep learning algorithms, in terms of defining health degradation performance. We expect that the proposed SAAT-based health feature space approach will be widely applicable to intuitively monitor the health state of power transformers in the real world.

Highlights

  • Power transformers are important components of distribution and transmission lines of power grid systems

  • The method was tested using a large amount of Dissolved gas analysis (DGA) datasets provided by Korea Electric Power Corporation (KEPCO)

  • The proposed idea consists of three main steps: 1) preprocessing DGA data, 2) extracting two health features by supervised autoencoder with an auxiliary task (SAAT) method, and 3) visualizing the two health features into two-dimensional space, a so-called health feature space (HFS)

Read more

Summary

INTRODUCTION

Power transformers are important components of distribution and transmission lines of power grid systems. A semi-supervised learning approach using a low-dimensional scaling was developed to consider unlabeled DGA data [28]. This approach has difficulty performing health feature selection for unlabeled datasets. Deep learning techniques, such as by sparse autoencoder [33] and deep belief network [34], have been used to extract high-level health features by unsupervised greedy layer wise training with deep hierarchical hidden layers. While these advances have been significant, AI-based approaches have the following three limitations.

BACKGROUND
AUTOENCODER
SOFTMAX CLASSIFIER
SEMI-SUPERVISED AUTOENCODER
SAAT-BASED FAULT DIAGNOSIS METHOD
PERFORMANCE EVALUATION OF THE PROPOSED METHOD
Findings
CONCLUSION

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.