Abstract

A semi-automated system has been designed and installed for the routine production of highly concentrated solutions of rhenium-188 perrhenate in saline which incorporates extensive radiation protection for the laboratory staff. This new system represents a simple, rapid, and effective computer controlled method using inexpensive disposable components. The flipper-valve settings and the radioactivity measured by use of collimated gamma dose rate probes are continuously monitored. If necessary, 2–3 tungsten-188/rhenium-188 generators can be eluted in a tandem arrangement. Eluate volumes (1.3–2 ml) of maximum specific radioactivity of 25 GBq/ml were routinely prepared.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.