Abstract

This paper introduces the principle and design of an ultrasonic transducer system with auto-alignment mechanism. The proposed system is used for detecting foreign bodies (FBs) in beverage containers. Variation in reflection amplitude is analyzed as a function of the ultrasound beam incident angle to beverage container surface. It is concluded that there exists a quadratic relationship between the strength of the reflected signal and the incident angle. Furthermore, a calculation for effective angular increment for searching the normal of a curved surface is introduced. Experiments conducted using the prototype demonstrated that FBs are detectable in various juices. Experiments also observed some false echo signals that occur due to curved container surface. Threshold in confined time region is therefore set to ensure no fail of detection in low signal to noise ratio. This design is also applicable to non-destructive inspection for metal canned food.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.