Abstract
We have operated successfully glass resistive plate counters in the streamer mode at the BELLE experiment by using a nonflammable gas mixture of argon 30%, butane-silver 8%, and freon, HFC-134a 62%. This freon is non-ozone-depleting but has a high global warming potential (1300 times higher than that of CO/sub 2/). Thus freon gases might be unusable in the near future. We tested the performance of a glass resistive plate counter operated in the streamer mode with an alternative gas mixtures of argon, butane, CO/sub 2/, and/or O/sub 2/ gases and found an efficiency of about 90%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.