Abstract

In this paper, we show how the published literature reveals that the approximate two-dimensional solution for the stress intensity factor associated with cracked panel repaired using an externally bonded composite repair is inconsistent with experimental data, and that for short to mid-size cracks the fibre bridging effect is often a second-order effect. The result of this finding is that prediction of the effect of a composite repair on the structural integrity of cracked components repaired by an externally bonded composite repair is dramatically simplified. We also show why structures repaired using Glare patches have a fatigue performance that is superior to structures repaired using boron epoxy or carbon fibre patches.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.