Abstract
Buck-buck/Boost power factor correction (PFC) converter is a great choice to compensate the inherent dead zones in the input current of buck PFC converter. However, whether the converter operates with traditional constant on-time control in critical conduction mode (CRM) or with conventional constant duty-cycle control in discontinuous conduction mode (DCM), the power factor (PF) is low, especially at low input voltage. Therefore, fixed on-time ratio control (FOTRC) and fixed duty-cycle ratio control (FDCRC) are proposed for CRM/DCM buck-buck/boost PFC converter to achieve high PF, respectively. Both control methods maximize PF over wide input voltage range by adjusting on-time or duty-cycle of buck/boost mode and buck mode. Compared with the traditional controls, the proposed control methods also have advantage of increasing efficiency. Furthermore, for improving dynamic response performance, smooth and rapid dynamic response control (SRDRC) is put forward, which can reduce the regulation time and output voltage overshoot/undershoot when the load or input voltage changes abruptly. In addition, the implementation circuits combining FOTRC/FDCRC and SRDRC are designed. Two prototypes have been built and tested in the lab to demonstrate the validity of the theoretical analysis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.