Abstract

When designing clinical trials, researchers often encounter the uncertainty in the treatment effect or variability assumptions. Hence the sample size calculation at the planning stage of a clinical trial may also be questionable. Adjustment of the sample size during the mid-course of a clinical trial has become a popular strategy lately. In this paper we propose a procedure for calculating additional sample size needed based on conditional power, and adjusting the final-stage critical value to protect the overall type-I error rate. Compared to other previous procedures, the proposed procedure uses the definition of the conditional type-I error directly without appealing to an extra special function for it. It has better flexibility in setting up interim decision rules and the final-stage test is a likelihood ratio test.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.