Abstract

In the present paper, the simultaneous spectrophotometric estimation of Metformin (MET) and Pioglitazone (PIO) in an antidiabetic drug called Actoplus MET based on least squares support vector machine (LS-SVM) was proposed. The optimum gamma (γ) and sigma (σ) parameters were found to be 825 and 90 with the root mean square error (RMSE) of 0.1343for MET, as well as 1000 and 350 with RMSE=0.4120 for PIO. Also, the mean recovery values of MET and PIO were 99.81% and 100.19%, respectively. Ultimately, the real sample was analyzed by High-Performance Liquid Chromatography (HPLC) reference method and the proposed procedure. Then, one-way analysis of variance (ANOVA) test at the 95 % confidence level was performed on achieved results from HPLC and LS-SVM methods. The statistical data of these methods showed that there were no significant differences between them.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.